Dissolved Oxygen
Laboratory Dissolved Oxygen Electrodes:
Laboratory Dissolved Oxygen Electrodes:
Sentek, Galvanic DO Electrode
- Temperature Range 0 – 40°C
- Pressure 1 BAR
- Linearity Straight Line
- Output Zero mV in sodium sulphate solution, 35-55mV in air
- Shaft Length 120mm ± 2mm
- ATC Can be fitted on receipt of required value
- Shelf Life 24 months
- Measuring Range 0 – 200%
Jenco, LD-900G-1
- DO Range 0 to 200.0% or 0 to 20 mg/L(ppm)
- Response Time 30 secs to attain 95% of actual reading(25 °C)
- Length 140 mm, Diamter 12 mm
- Type Galvanic
- BODY METERIAL Epoxy
- Sensor Meterial Pb and Ag
- Cable Length 4 m, Connector 6 pin
Q-I-S, QD2400T
- Range 0..200% - 0..20mg/l
- Temperature range (°C) 0..60
- Shaft material PPS
- Shaft diameter (mm) 12
- Shaft length (mm) 120
- Cable length (m) 1,8
- Connector BNC/RCA (cinch)
- ATC NTC 22kOhm
Sentek, Polarographic DO sensor
- Designed for laboratory measurements.
- Standard 12mm body diameter.
- Output at saturation 600nA.
- Output at Zero Oxygen <1% saturation.
- Polarisation Voltage 800mV.
- Membrane Teflon
Industrial Dissolved Oxygen Electrodes:
Industrial Dissolved Oxygen Electrodes:
Jenco, LD-900-10/11
- DO Range 0 ~ 20.00 mg/L (ppm) / 0 ~ 200.0%
- Operating Temperature -6 ~ 46 °C
- Temperature Sensor 10 K NTC
- Response Time 30 secs to attain 95% of actual reading(at 25 °C)
- Sensor Material Gold and Ag
- Type Polarographic
- Connector 8 pin / 6 pin
- Cable Length 4 m or other
Jenco, Oxysens 120
- DO Range 0 ~ 40 ppm (mg/L)
- Temperature Range 0 to 60 °C
- Pressure Tolerance 0 to 4 bar
- Response Time 60 secs to attain 98% of actual reading
- Temperature Sensor NTC 22K °C
- Thread PG 13.5
- Connector Free
- Cable Length 5 m or other
Wedgewood Analytical ,OOS41
- Measuring principle membrane-covered amperometric sensor
- Temperature Range 0 to 50 °C
- Max. permissible over pressure 10 bar
- Degree of protection IP 68
- Threaded connection G 1 and NPT ¾"
- Cable lengths 7 m, 15 m, Max. cable extension 50 m
- Weight without packaging (for cable length) 0.7 kg (7 m) or 1.1 kg (15 m)
Wedgewood Analytical ,OOS51D
- Measuring principle Amperometric oxygen measurement
- Measurement range 0.01 to 100 mg/l
- Dimension Diameter: 40mm(1.57 inch) Shaft length: 144 mm (5.67 inch)
- Process temperature -5 to 50 °C (20 to 120 °F)
- Process pressure max. 10 bar (max. 145 psi)
- Connection Memosens connector Process: G1, NPT 3/4"
Steam Sterlisable DO2 Electrodes
Endress Hauser Conducta, OCOS22D
- Measuring principle Amperometric oxygen measurement
- Standard process connection Pg 13.5
- Measurement range 0.001 to 20 mg/l
- Measuring principle
- Dimension Diameter: 12 mm (0.47 inch),Shaft length: 120, 225, 360 and 420 mm
(4.72, 8.86, 14.2 and 16.5 inch) - Process temperature -5 to 135 °C (23 to 275 °F)
- Process pressure 1 to 12 bar abs (14.5 to 174 psi)
- Temperature sensor Integrated NTC temperature sensor
- Connection Memosens-connection head
Industrial Optical DO2 Electrodes are also available...
Industrial Optical DO2 Electrodes are also available...
..and for many more types of DO sensors, contact sales@innovativeanalyticals.net