Industrial Instruments

Industrial Instruments For pH/ORP

Jenco, 3661
  • Easy to install 1/8 DIN plastic casing.
  • Clear LCD displays pH, mV, or temperature with backlight.
  • Universal power supply input from 100 to 240 V AC.
  • Automatic or manual temperature compensation.
  • Displays absolute and relative ORP.
  • 4 to 20 mA current output for pH or ORP allows it to be used as a proportional output.
Sensorex, TX10
  • Easy to install 1/8 DIN Case
  • 4-20mA current output
  • Clear LCD displays pH or ORP and temperature
  • 100-240 VAC power supply
  • Measurement Range (pH): -2.00 to 16.00pH, 0.01 pH resolution, +/- 0.1% accuracy
  • Measurement Range (ORP/mV): -1999mV to 1999mV, 1mV resolution, +/- 0.1% accuracy
  • Power Requirement: 100-240 VAC, max 500 ohm load
Sensorex, TX100
  • pH: 0.00 to 14.00 pH, 0.01 pH resolution, ± 0.01 Accuracy
  • ORP/mV: -1999mV to 1999mV, 1mV resolution, ± 2mV accuracy
  • Temperature: -20°C (-4°F) to 110°C (230°F), 0.1° C/F resolution
  • Current Output Range: 2.00mA to 24mA, .01mA
  • Resolution, ±0.005mA
  • Dimensions : 3.9’’ (99.1 mm) H x 3.9’’ (99.1mm) W x 2.9’’ (74.7mm) D
Wedgewood Analytical, OPM223
  • Panel-mounted housing
  • Simple handling:Large two-line display, Ultrasimple two-point calibration
  • Safe operation: Overvoltage (lightning) protection, Direct access for manual contact control, Calibration plausibility check, User-defined alarm
  • 2nd current output for temperature, pH/ORP, or continuous controller 
Sensorex, TX105
  • Measurement Range (pH): 0.00 to 14.00pH, 0.01 pH resolution, +/- 0.01 accuracy
  • Measurement Range (ORP/mV): -1999mV to 1999mV, 1mV resolution, +/- 2mV accuracy
  • Temperature Range: -20 °C to 110 °C , 0.1 °C resolution, 0.2 °C accuracy
  • Current Output Range: 2.00mA to 24mA, 0.01mA resolution, +/-0.005mA accuracy, 500V input/output isolation
Jenco, 6311
  • pH/ORP/temperature measurement & control
  • User selectable ATC element: 3k balco, 10k, and pt-1000
  • Reversible & isolated 4 ~ 20 mA output
  • RS-485 output
  • Graphic LCD dispaly,128 x 64with backlight
  • High 50/60 Hz noise rejection
  • Pipe/wall/panel mounting
  • One programmable relay for wash.
Wedgewood Analytical, OPM253
  • Field-mounted housing
  • Simple handling:Large two-line display, Ultrasimple two-point calibration
  • Safe operation: Overvoltage (lightning) protection, Direct access for manual contact control, Calibration plausibility check, User-defined alarm
  • 2nd current output for temperature, pH/ORP, or continuous controller 
Jenco, pH39002-wire pH transmitter (4-20mA) 
  • Clear LCD displays pH
  • Isolated 4 to 20 mA current output for pH
  • Wide range power supply, 11 to 50 V DC
  • Automatic temperature compensation
  • Easy to install for wall setting
  • IP65 watertight casing
  • Isolated two wires 4 to 20 mA

Industrial Instruments For Conductivity/TDS

Wedgewood Analytical, OLM223
  • Panel-mounted housing
  • Simple handling:Large two-line display, Ultrasimple two-point calibration
  • Safe operation: Overvoltage (lightning) protection, Direct access for manual contact control, Calibration plausibility check, User-defined alarm
  • 2nd current output for temperature, pH/ORP, or continuous controller 
Sensorex, CX20
  • Cell Constant: 0.01, 0.1, 1.0 (2 electrode)
  • Temperature Sensor: Thermistor: 10k ohm at 25°C
  • Operating Temperature: -10°C to 120°C (+/- 0.3°C, 0.1°C resolution)
  • Relays: 5A at 115VAC or 2.5A at 220VAC (resistive only)
  • Maximum Load: 500 ohm
  • Output Accuracy: +/- 0.03mA
  • Power: 100VAC to 240VAC, 50/60Hz
Sensorex, TCSTX
  • Input: Accepts Sensorex TCS and TCSP sensors
  • Full Scale Range: 0-2,000 uS / 2.000 mS / 20.00 mS/ 200.0 mS / 2,000 mS – User selectable
  • Operating Conditions: -20 to 60deg C (-4 to 140 deg F), 0-95% R.H. non-condensing conditions
  • Power Requirement: 16-35V DC (2-wire device)
  • Output Isolation: 600 V galvanic isolation
Digital Instruments, 512 GCL
  • Cell Constant K = 0.01, 0.1, 0.5, 1.0, & 10 ( User Selectable ) *
  • Temperature Range 0.0 to 200.0 c
  • Control Relay O/P Two 5 Amp. 24V Contacts Free Relay
  • Supply 230 V A.C , +/- 10 V, 50 Hzs
  • Instruments Size & Type 96 x 96 x 70 mm
  • Panel Mount Type (Grey High Quality ABS Plastic Housing)
Jenco, 3331
  • Easy to install 1/8 DIN plastic casing.
  • Clear LCD displays conductivity, resistivity or temperature with backlight.
  • Universal power supply input from 100 to 240 V AC.
  • Automatic or manual temperature compensation.
  • Isolated and reversible 4 to 20 mA current output for conductivity or resistivity allows
    it to be used as a proportional output.
  • RoHS, CE compliant.
Sensorex, CX105
  • Display: LCD: 128*65 dot matrix, figure or alphabet: 12×8, 28×15, 32×18, etc., 
  • Conductivity: 0.05 to 500,000 μS/cm
  • Isolated 4-20 mA output with 0.004 mA (12-bit) resolution
  • Power: 19 -48VDC, regulated, 30mA maximum
  • Maximum Loop Impedance: 250Ω@24V; 600Ω@31V; 1500Ω@48V
Wedgewood Analytical, OLM253
  • Field-mounted housing
  • Simple handling: Logically arranged menu structure, Ultrasimple two-point calibration
  • Safe operation: Overvoltage (lightning) protection, Direct access for manual contact control, User-defined alarm configuration
  • 2nd current output for temperature, main measured value, or actuating variable
  • Current input for flow rate monitoring with controller shut off or for feedforward control 
Sensorex, EX2000RS(Toroidal Conductivity Monitoring System)
  • The EX2000RS toroidal conductivity transmitter has one 4-20 mA output,.
  • An RS-485 serial interface for use with Modbus RTU or ASCII, and can display conductivity, percent concentration, TDS, and salinity. 
  • Use either the durable Noryl-body TCS3020 Toroidal Conductivity / TDS Sensor or the TCS3020 PEEK Toroidal Conductivity / TDS Sensor. 
  • Both are resistant to fouling, coating, and corrosion and require virtually no maintenance.

Other Industrial Instruments

EH Conducta: OCM42 

  • Measuring principle ISFET
  • Liquiline M CM42 is a modular two-wire transmitter for all areas of process engineering
  • Input One channel transmitter for Memosens and analog (pH, ORP, conductivity)
  • Output / communication 1/2 x 4 to 20 mA, HART, Profibus PA, FF
    Additional second output possible

OCM44R

  •  Highly flexible:
  • Able to connect up to 8 Memosens sensors
  • Mathematics functions calculate new measured values
  • Digital fieldbuses (HART, PROFIBUS, Modbus, Ethernet/IP, PROFINET) and integrated webserver
  • Choice of cleaning function, controller, and alarm relay
  • Optional digital or analog inputs/outputs 

...and many more types of Industrial Instruments , contact sales@innovativeanalyticals.net