Industrial Instruments
Industrial Instruments For pH/ORP
Industrial Instruments For pH/ORP
Jenco, 3661
- Easy to install 1/8 DIN plastic casing.
- Clear LCD displays pH, mV, or temperature with backlight.
- Universal power supply input from 100 to 240 V AC.
- Automatic or manual temperature compensation.
- Displays absolute and relative ORP.
- 4 to 20 mA current output for pH or ORP allows it to be used as a proportional output.
Sensorex, TX10
- Easy to install 1/8 DIN Case
- 4-20mA current output
- Clear LCD displays pH or ORP and temperature
- 100-240 VAC power supply
- Measurement Range (pH): -2.00 to 16.00pH, 0.01 pH resolution, +/- 0.1% accuracy
- Measurement Range (ORP/mV): -1999mV to 1999mV, 1mV resolution, +/- 0.1% accuracy
- Power Requirement: 100-240 VAC, max 500 ohm load
Sensorex, TX100
- pH: 0.00 to 14.00 pH, 0.01 pH resolution, ± 0.01 Accuracy
- ORP/mV: -1999mV to 1999mV, 1mV resolution, ± 2mV accuracy
- Temperature: -20°C (-4°F) to 110°C (230°F), 0.1° C/F resolution
- Current Output Range: 2.00mA to 24mA, .01mA
- Resolution, ±0.005mA
- Dimensions : 3.9’’ (99.1 mm) H x 3.9’’ (99.1mm) W x 2.9’’ (74.7mm) D
Wedgewood Analytical, OPM223
- Panel-mounted housing
- Simple handling:Large two-line display, Ultrasimple two-point calibration
- Safe operation: Overvoltage (lightning) protection, Direct access for manual contact control, Calibration plausibility check, User-defined alarm
- 2nd current output for temperature, pH/ORP, or continuous controller
Sensorex, TX105
- Measurement Range (pH): 0.00 to 14.00pH, 0.01 pH resolution, +/- 0.01 accuracy
- Measurement Range (ORP/mV): -1999mV to 1999mV, 1mV resolution, +/- 2mV accuracy
- Temperature Range: -20 °C to 110 °C , 0.1 °C resolution, 0.2 °C accuracy
- Current Output Range: 2.00mA to 24mA, 0.01mA resolution, +/-0.005mA accuracy, 500V input/output isolation
Jenco, 6311
- pH/ORP/temperature measurement & control
- User selectable ATC element: 3k balco, 10k, and pt-1000
- Reversible & isolated 4 ~ 20 mA output
- RS-485 output
- Graphic LCD dispaly,128 x 64with backlight
- High 50/60 Hz noise rejection
- Pipe/wall/panel mounting
- One programmable relay for wash.
Wedgewood Analytical, OPM253
- Field-mounted housing
- Simple handling:Large two-line display, Ultrasimple two-point calibration
- Safe operation: Overvoltage (lightning) protection, Direct access for manual contact control, Calibration plausibility check, User-defined alarm
- 2nd current output for temperature, pH/ORP, or continuous controller
Jenco, pH39002-wire pH transmitter (4-20mA)
- Clear LCD displays pH
- Isolated 4 to 20 mA current output for pH
- Wide range power supply, 11 to 50 V DC
- Automatic temperature compensation
- Easy to install for wall setting
- IP65 watertight casing
- Isolated two wires 4 to 20 mA
Industrial Instruments For Conductivity/TDS
Industrial Instruments For Conductivity/TDS
Wedgewood Analytical, OLM223
- Panel-mounted housing
- Simple handling:Large two-line display, Ultrasimple two-point calibration
- Safe operation: Overvoltage (lightning) protection, Direct access for manual contact control, Calibration plausibility check, User-defined alarm
- 2nd current output for temperature, pH/ORP, or continuous controller
Sensorex, CX20
- Cell Constant: 0.01, 0.1, 1.0 (2 electrode)
- Temperature Sensor: Thermistor: 10k ohm at 25°C
- Operating Temperature: -10°C to 120°C (+/- 0.3°C, 0.1°C resolution)
- Relays: 5A at 115VAC or 2.5A at 220VAC (resistive only)
- Maximum Load: 500 ohm
- Output Accuracy: +/- 0.03mA
- Power: 100VAC to 240VAC, 50/60Hz
Sensorex, TCSTX
- Input: Accepts Sensorex TCS and TCSP sensors
- Full Scale Range: 0-2,000 uS / 2.000 mS / 20.00 mS/ 200.0 mS / 2,000 mS – User selectable
- Operating Conditions: -20 to 60deg C (-4 to 140 deg F), 0-95% R.H. non-condensing conditions
- Power Requirement: 16-35V DC (2-wire device)
- Output Isolation: 600 V galvanic isolation
Digital Instruments, 512 GCL
- Cell Constant K = 0.01, 0.1, 0.5, 1.0, & 10 ( User Selectable ) *
- Temperature Range 0.0 to 200.0 c
- Control Relay O/P Two 5 Amp. 24V Contacts Free Relay
- Supply 230 V A.C , +/- 10 V, 50 Hzs
- Instruments Size & Type 96 x 96 x 70 mm
- Panel Mount Type (Grey High Quality ABS Plastic Housing)
Jenco, 3331
- Easy to install 1/8 DIN plastic casing.
- Clear LCD displays conductivity, resistivity or temperature with backlight.
- Universal power supply input from 100 to 240 V AC.
- Automatic or manual temperature compensation.
- Isolated and reversible 4 to 20 mA current output for conductivity or resistivity allows
it to be used as a proportional output. - RoHS, CE compliant.
Sensorex, CX105
- Display: LCD: 128*65 dot matrix, figure or alphabet: 12×8, 28×15, 32×18, etc.,
- Conductivity: 0.05 to 500,000 μS/cm
- Isolated 4-20 mA output with 0.004 mA (12-bit) resolution
- Power: 19 -48VDC, regulated, 30mA maximum
- Maximum Loop Impedance: 250Ω@24V; 600Ω@31V; 1500Ω@48V
Wedgewood Analytical, OLM253
- Field-mounted housing
- Simple handling: Logically arranged menu structure, Ultrasimple two-point calibration
- Safe operation: Overvoltage (lightning) protection, Direct access for manual contact control, User-defined alarm configuration
- 2nd current output for temperature, main measured value, or actuating variable
- Current input for flow rate monitoring with controller shut off or for feedforward control
Sensorex, EX2000RS(Toroidal Conductivity Monitoring System)
- The EX2000RS toroidal conductivity transmitter has one 4-20 mA output,.
- An RS-485 serial interface for use with Modbus RTU or ASCII, and can display conductivity, percent concentration, TDS, and salinity.
- Use either the durable Noryl-body TCS3020 Toroidal Conductivity / TDS Sensor or the TCS3020 PEEK Toroidal Conductivity / TDS Sensor.
- Both are resistant to fouling, coating, and corrosion and require virtually no maintenance.
Other Industrial Instruments
Other Industrial Instruments
EH Conducta: OCM42
- Measuring principle ISFET
- Liquiline M CM42 is a modular two-wire transmitter for all areas of process engineering
- Input One channel transmitter for Memosens and analog (pH, ORP, conductivity)
- Output / communication 1/2 x 4 to 20 mA, HART, Profibus PA, FF
Additional second output possible
OCM44R
- Highly flexible:
- Able to connect up to 8 Memosens sensors
- Mathematics functions calculate new measured values
- Digital fieldbuses (HART, PROFIBUS, Modbus, Ethernet/IP, PROFINET) and integrated webserver
- Choice of cleaning function, controller, and alarm relay
- Optional digital or analog inputs/outputs
...and many more types of Industrial Instruments , contact sales@innovativeanalyticals.net